Validity and Reliability of Two Smartphone Applications on Heart Rate Variability in Healthy Subjects

Main Article Content

Sirinut Chaiduang
Jirawat Wattanapanyawech

บทคัดย่อ

Heart rate variability (HRV) parameters represent the body's autonomic activity. The approach to obtaining these parameters needs special equipment. Interestingly, smartphone applications (apps) have recently become more friendly. With Polar H10, Elite app has good validity and reliability. HRVlogger is another fascinating app with more sophisticated in functionality. This study aims to determine the validity and reliability between Elite HRV and HRV logger application implementing the same chest strap, Polar H10, on heart rate variability parameters in healthy subjects. Twenty-six healthy adults performed three consecutive five-minute HRV recordings with one minute rest in both app during sitting. There were three correlations with the highest strength, natural log of the root mean square of successive differences between normal heartbeats (LnRMSSD) (r = 0.95, p-value < 0.01), the percentage of adjacent normal to normal intervals that differ from each other by more than 50 ms (pNN50), (r = 0.94, p-value < 0.01), and RR interval (r = 0.93, p-value < 0.01). The excellent correlation was root mean square of successive differences between normal heartbeats (RMSSD), heart rate (HR), and standard deviations of all the NN intervals (SDNN). The values were 0.88, 0.86, and 0.84, respectively (p-value < 0.01). Moreover, the low frequency/high frequency (LF/HF) ratio had moderate correlation (r = 0.59, p-value < 0.01). Reliability was excellent. RMSSD is 0.93 (0.84, 0.97), LnRMSSD is 0.97 (0.94, 0.99), HR is 0.97 (0.94, 0.99), RR interval is 0.97 (0.92, 0.94), SDNN is 0.90 (0.78, 0.96), and pNN50 is 0.94 (0.87, 0.97). The LF/HF ratio is poor to moderate, 0.38 (-0.39,0.72). HRV logger has moderate to excellent validity and reliability.

Article Details

How to Cite
Chaiduang, S., & Wattanapanyawech, J. . (2025). Validity and Reliability of Two Smartphone Applications on Heart Rate Variability in Healthy Subjects . วารสารเทคโนโลยีทางการแพทย์และสหเวชศาสตร์, 1(1), e2893. สืบค้น จาก https://he04.tci-thaijo.org/index.php/JMAS/article/view/2893
บท
บทความวิจัย

References

Dobbs, W. C., Fedewa, M. V., MacDonald, H. V., Holmes, C. J., Cicone, Z. S., Plews, D. J., & Esco, M. R. (2019). The accuracy of acquiring heart rate variability from portable devices: a systematic review and meta-analysis. Sports Medicine, 49(3), 417–435. https://doi.org/10.1007/s40279-019-01061-5

Gambassi, B. B., Neves, V. R., Brito, E. Z. A., da Silva Fernandes, D. S., Sá, C. A., da Rocha Nogueira, R. M., de Jesus Furtado Almeida, F., de Araújo Cavalcanti, P. A., Gomes Gonçalves E Silva, D. C., Neto, D. S., de Souza Mesquita, F. O., Novais, T. M. G., de Souza, V. F. M., Oliveira, A. C. C., Leite, R. D., & Schwingel, P. A. (2020). A validation study of a smartphone application for heart rate variability assessment in asymptomatic adults. American journal of cardiovascular disease, 10(3), 219–229.

https://pmc.ncbi.nlm.nih.gov/articles/PMC7486523/

Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019). RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise. European Journal of Applied Physiology, 119(7), 1525–1532. https://doi.org/10.1007/s00421-019-04142-5

Moya-Ramon, M., Mateo-March, M., Peña-González, I., Zabala, M., & Javaloyes, A. (2022). Validity and reliability of different smartphones applications to measure HRV during short and ultra-short measurements in elite athletes. Computer Methods and Programs in Biomedicine, 217, 106696. https://doi.org/10.1016/j.cmpb.2022.106696

Perrotta, A. S., Jeklin, A. T., Hives, B. A., Meanwell, L. E., & Warburton, D. E. R. (2017). Validity of the elite HRV smartphone application for examining heart rate variability in a field-based setting. Journal of Strength and Conditioning Research, 31(8), 2296–2302. https://doi.org/10.1519/JSC.0000000000001841

Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006). Heart rate variability: a review. Medical & Biological Engineering & Computing, 44(12), 1031–1051. https://doi.org/10.1007/s11517-006-0119-0

Schober, P., Boer, C., & Schwarte, L. A. (2018). Correlation coefficients: appropriate use and interpretation. Anesthesia and Analgesia, 126(5), 1763–1768. https://doi.org/10.1213/ANE.0000000000002864

Shaffer, F., & Ginsberg, J. P. (2017). An overview of heart rate variability metrics and norms. Frontiers in Public Health, 5, Article 258. https://doi.org/10.3389/fpubh.2017.00258

Speer, K. E., Semple, S., Naumovski, N., & McKune, A. J. (2020). Measuring heart rate variability using commercially available devices in healthy children: a validity and reliability study. European Journal of Investigation in Health, Psychology and Education, 10(1), 390–404. https://doi.org/10.3390/ejihpe10010029