ประโยชน์และข้อจำกัดในการตรวจน้ำตาลในเลือดด้วยเครื่องตรวจชนิดอัตโนมัติ Point-of-Care Testing (POCT) for Blood Glucose: Benefits and Pitfalls
Main Article Content
Article Details
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
References
Van den Berghe G, Wouters P, Weekers F, Verwaest C, Bruyninckx F, Schetz M, et al. Intensive insulin therapy in the critically ill patients. N Engl J Med 2001; 345:1359-67.
Malmberg K, Ryden L, Efendic S, Herlitz J, Nicol P, Waldenstrom A, et al. Randomized trial of insulin-glucose infusion followed by subcutaneous insulin treatment in diabetic patients with acute myocardial infarction (DIGAMI study): effect on mortality at 1 year. J Am Coll Cardiol 1995; 26: 57-65.
Finfer S, Chittock DR, Su SY, Blair D, Foster D, Dhingra V, et al. Intensive versus conventional glucose control in critically ill patients. N Engl J Med 2009; 360: 1283-97.
Moghi E.S., Korytkowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, et al. American Association of Clinical Endocrinologists; American Diabetes Association consensus statement on inpatient glycemic control. Diabetes Care 2009; 32: 1119-31.
Kanji S, Buffie J, Hutton B, Bunting P, Singh A, McDonald K, et al. Reliability of point-of-care testing for glucose measurement in critically ill adults. Crit Care Med. 2005; 33: 2778-85.
Shearer A, Boehmer M, Closs M, Dela Rosa R, Hamilton J, Horton K, et al. Comparison of glucose point-of-care values with laboratory values in critically ill patients. Am J Crit Care 2009; 18: 224-30.
Duncan K, Chapman J, Braithwaite S, Buse J. Glucose measuring: confounding issues in setting targets for inpatient management. Diabetes Care 2007; 30: 403-9.
Atkin SH, Dasmahapatra A, Jaker MA, Chorost M, Reddy S. Fingerstick glucose determination in shock. Ann Intern Med 1991; 114: 1020-4.
Tang Z, Lee JH, Louie RF, Kost GJ. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of –care testing. Arch Pathol Lab Med 2000; 124: 1135-40.
Louie RF, Tang Z, Sutton DV, Lee JH, Kost GJ. Pointof-care glucose testing: effects of critical care variables, influence of reference instruments, and a modular glucose meter design. Arch Pathol Lab Med 2000; 124: 257-66.
Tang Z, Louie RF, Payer M, Chang KC,Kost GJ. Oxygen effects on glucose measurements with a reference analyzer and three handheld meters. Diabetes Technol Ther 2000; 2: 349-62.
Soller BR, Idwasi PO, BalaguerJ, Levin S, Simsir SA, Vander Salm TJ, et al. Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass. Crit Care Med 2003; 31: 2324-31.
Oberg D, Ostenson CG. Performance of glucose dehydrogenase-and glucose oxidased-based blood glucose meter at high attitude and low temperature. Diabetes Care 2005; 28: 1261.
Haupt A, Berg B, Paschen P, Dreyer M, Haring HU, Smedegaard J, et al. The effects of skin temperature and testing site on blood glucose measurement taken by a modern blood glucose monitoring device. Diabetes Technol Ther 2005; 7: 597-601.
Tang Z, Du X, Louie RF, Kost GJ. Effects of pH on glucose measurement with handheld glucose meters and a portable glucose glucose analyser for point-of-care testing. Arch Pathol Lab Med 2000; 124: 577-82.
Kilpatrick ES, Rumley AG, Smith EA. Variations in sample pH and pO2 affect Exac Tech meter glucose measurements. Diabet Med 1994; 11: 506-9.
Tang Z, Du X, Louie RF, Kost GJ. Effects of drugs on glucose measurement with handheld glucose meters and a portable glucose analyzer. Am J Clin Pathol 2000; 113: 75-86.
Katelijne MJ, Delanghe J. Analytic interferences in pointof-care testing glucometers by icodextrin and its metabolites: and overview. Perit Dial Int 2009; 29: 377-83.
Rainey PM, Jatlow P. Monitoring blood glucose meters. Am J Clin Pathol 1995; 103: 125-6.
Sacks D, Bruns D, Goldstein D, Mackaren N, Mc Donald J, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002; 48: 436-72.
Farrer M, Albers CJ, Neil HA, Adams PC, Laker MF, Alberti KG. Assessing the impact of blood sample type on the estimated prevalence of impaired glucose tolerance and diabetes mellitus in epidemiological surveys. Diabete Med 1995; 12: 325-9.
Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accuracy results. J Diabetes Sci Technol 2009; 3: 971-80.